logo

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Leak Testing Equipment
Created with Pixso.

15KW Helium Recovery Machine with ≥90% Helium Recovery Rate and ≤3s Recovery Time for Leak Testing

15KW Helium Recovery Machine with ≥90% Helium Recovery Rate and ≤3s Recovery Time for Leak Testing

Brand Name: HeJin
Model Number: HJ-HS-3
MOQ: 1 Set
Price: Negotiatable
Payment Terms: L/C,T/T
Supply Ability: 10 set per 3 months
Detail Information
Place of Origin:
Guangzhou,Guangdong,China
Certification:
Third party calibration certificate/ CE(cost additional)
Model:
HJ-HS-3
Recovery Rate:
≥90%
Power Consumption:
15KW
Recovery Time:
≤3s
Charging Pressure:
0.5–0.25 MPa
Concentration Accuracy:
±5%
Equipment Length:
≤2200 Mm
Equipment Width:
≤2000 Mm
Packaging Details:
Plywood
Highlight:

15KW Helium Recovery Machine

,

≥90% Helium Recovery Rate Machine

,

≤3s Recovery Time Helium Recovery System

Product Description

The Industrial Helium Recovery Machine is designed to recover and reuse helium gas from industrial leak testing processes. With a specified helium recovery rate of ≥90%, it helps manufacturers reduce fresh helium consumption, control operating costs and improve gas utilization. Developed and manufactured by HeJin, this helium recovery system can be integrated with compatible helium leak testing equipment to support continuous production and more efficient gas management.

Product Introduction

Helium is an important tracer gas in precision leak testing, but repeatedly releasing unused helium after each testing cycle can create unnecessary operating expenses.

HeJin's Helium Recovery Machine provides a practical solution by collecting and recovering helium from connected leak testing systems. Instead of allowing reusable gas to be wasted after testing, the system helps return recovered helium to the production process.

Designed for industrial manufacturing environments, this equipment supports helium recovery operations for automotive components, refrigeration products, heat exchangers and other sealed products.

As a direct manufacturer, HeJin combines equipment research and development, engineering design and in-house production. We focus on building helium recovery solutions that match actual production requirements rather than offering a one-size-fits-all configuration.

Product Features
High Helium Recovery Efficiency

The specified helium recovery rate is ≥90%, helping manufacturers reduce the amount of fresh helium required during repeated leak testing operations.

Fast Recovery Process

The specified recovery time is ≤3 seconds under the stated operating condition, supporting efficient gas recovery within the production cycle.

Accurate Helium Concentration Control

The specified helium concentration accuracy is ±5%, helping maintain controlled gas conditions for compatible leak testing applications.

Industrial Equipment Configuration

With a listed power consumption of 15KW and a compact integrated equipment layout, the system is designed for industrial production environments.

Flexible System Integration

The recovery machine can be evaluated for connection with existing helium leak testing equipment. Connection interfaces, gas flow requirements and control logic should be confirmed before installation.

Manufacturer-Direct Engineering Support

HeJin provides technical communication, equipment design, manufacturing, installation guidance and after-sales support.

Main Functions
  • Recover reusable helium from connected leak testing equipment.
  • Reduce unnecessary helium discharge during production.
  • Support helium gas circulation and reuse.
  • Help reduce fresh helium purchasing requirements.
  • Support controlled helium concentration management.
Technical Specifications
Item Specification
Product NameHelium Recovery Machine
ModelHJ-HS-3
Equipment CategoryHelium Recovery Equipment
ApplicationIndustrial Helium Leak Testing
Helium Recovery Rate≥90%
Energy Consumption15KW
Recovery Time≤3s
Helium Charging Pressure0.5–0.25 MPa (original listing; confirmation required)
Helium Concentration Accuracy±5%
Recovery Time Test ConditionExternal port pressure evacuated to below 70 mbar within 3 seconds
Equipment Length≤2200 mm
Equipment Width≤2000 mm
Equipment Height≤2500 mm
Overall Dimensions≤2200 × 2000 × 2500 mm
Calibration CertificateAvailable at additional cost
Technical Note: The specifications above are transcribed from the published HJ-HS-3 product information. The pressure range is displayed as 0.5–0.25 MPa in the source and requires engineering confirmation before publication as a finalized operating range. The original page also contains inconsistent 90% and 98% recovery claims. This description uses the detailed specification of ≥90% rather than presenting 98% as a guaranteed value. Additional specifications such as power supply voltage, gas flow capacity, inlet pressure, outlet pressure, connection size, noise level and equipment weight should be confirmed against the latest engineering datasheet before being added.
International Reference Standards

The helium recovery machine is used as part of an industrial gas recovery and leak testing process. The following international standards provide relevant technical references for the associated testing methods, equipment design and calibration.

ISO 20485:2017 – Non-destructive Testing: Leak Testing – Tracer Gas Method
  • Clause 1: Scope of tracer gas leak testing.
  • Clause 4: Principles of leak detection.
  • Clause 5: Generation and detection of tracer gas flow.
  • Clause 6: Testing apparatus.
  • Clause 7: Preparation of test objects.
  • Clause 8: Tracer gas flowing into the test object.
  • Clause 9: Tracer gas flowing out of the test object.
  • Clause 10: Test reporting.
ISO 20486:2017 – Non-destructive Testing: Calibration of Reference Leaks for Gases
  • Calibration of reference leaks used for leak detector adjustment.
  • Establishment of traceable reference leak values.
  • Support for reliable leak rate measurement in helium testing applications.
ISO 12100:2010 – Safety of Machinery: Risk Assessment and Risk Reduction
  • Clause 4: General principles for machinery risk assessment.
  • Clause 5: Risk assessment methodology.
  • Clause 6: Risk reduction.
  • Clause 7: Documentation and verification.
IEC 60204-1:2016 + AMD1:2021 – Safety of Machinery: Electrical Equipment of Machines
  • Clause 4: General requirements.
  • Clause 5: Incoming supply conductor terminations and devices for disconnecting and switching off.
  • Clause 7: Protection of equipment.
  • Clause 9: Control circuits and control functions.
  • Clause 10: Operator interface and machine-mounted control devices.
  • Clause 17: Technical documentation.

These standards provide technical references for the associated leak testing method, machinery design and electrical systems. They should not be interpreted as a claim that the HJ-HS-3 itself has been independently certified to every listed standard.

Suitable Applications

The helium recovery system can be considered for production facilities that regularly use helium leak testing equipment, including:

  • Automotive component manufacturing.
  • EV battery component production.
  • Automotive air conditioning systems.
  • Refrigeration and HVAC component manufacturing.
  • Heat exchanger production.
  • Cold plate and liquid cooling component testing.

The actual suitability depends on helium consumption, gas composition, operating pressure, connection compatibility and the customer's leak testing process.

What Can a Helium Recovery System Help Improve?
Helium Consumption Management

Recovering reusable helium helps reduce unnecessary gas loss during repeated production cycles.

Production Operating Costs

Lower fresh helium consumption can help manufacturers manage long-term consumable expenses.

Gas Utilization

A controlled recovery process makes better use of the helium already introduced into the leak testing process.

Production Integration

The recovery unit can be evaluated alongside existing helium leak testing equipment to develop a more coordinated gas supply and recovery arrangement.

Long-Term Process Management

A suitable recovery solution helps production teams manage helium usage more systematically.

Why Choose HeJin?

Choosing industrial equipment is not only about purchasing a machine. It is also about finding an engineering partner who understands the production process.

Direct Manufacturer

HeJin is a source manufacturer with in-house research, development, engineering design and production capabilities. Customers can communicate directly with the technical and manufacturing teams.

Customized Engineering

Different factories have different gas consumption levels, testing cycles and equipment layouts. We can evaluate the customer's existing system and discuss a suitable recovery configuration.

Integrated Leak Testing Experience

Our business covers helium leak detection equipment, vacuum testing systems, gas handling systems and automated testing solutions.

Quality-Focused Manufacturing

We emphasize equipment inspection, manufacturing process control and practical commissioning requirements.

Pre-Sales Technical Support

Our team can discuss workpiece applications, gas consumption, existing equipment interfaces and expected operating conditions before recommending a configuration.

After-Sales Service

We provide technical documentation, operating guidance, troubleshooting support and communication with customers during equipment installation and operation.

HeJin vs. Conventional Helium Gas Management
Comparison Conventional Gas Management HeJin Recovery Solution
Gas HandlingHelium may be discharged after testingSupports helium recovery and reuse
Fresh Gas DemandHigher when gas is repeatedly releasedHelps reduce fresh helium demand
Operating CostGreater exposure to helium consumption costsSupports consumable cost management
Production IntegrationMay rely on independent gas supply arrangementsCan be evaluated for system integration
Engineering SupportDepends on individual equipment suppliersDirect communication with manufacturer
CustomizationMay require separate engineering coordinationIn-house design and manufacturing support

The actual cost savings depend on helium consumption, gas leakage, recovery efficiency, production volume and operating conditions. A process-specific evaluation is recommended before calculating ROI.

Frequently Asked Questions
Q1: What is a helium recovery machine used for?

It collects reusable helium from connected leak testing equipment, helping reduce gas waste and fresh helium consumption.

Q2: What is the helium recovery rate of this machine?

The published HJ-HS-3 technical specification states a helium recovery rate of ≥90%.

Q3: Can it work with an existing helium leak testing machine?

Integration can be evaluated according to the existing equipment's gas interfaces, pressure requirements, flow rate and control arrangement.

Q4: Does helium recovery affect leak detection accuracy?

The recovery process should be configured to maintain suitable gas conditions for the connected testing process. Actual compatibility and test performance should be verified during engineering evaluation.

Q5: Can the equipment be customized?

Yes. HeJin can discuss customized engineering requirements according to production capacity, gas consumption and existing equipment configuration.

Q6: What information is needed to select a suitable helium recovery machine?

Useful information includes the existing leak testing equipment model, helium consumption per cycle, operating pressure, gas composition, recovery connection and daily production volume.

Q7: Does HeJin provide technical support after delivery?

Yes. HeJin provides technical communication, operating guidance, troubleshooting assistance and after-sales support.

About HeJin

HJ AUTOMATIC CONTROL TECHNOLOGY CO., LTD was established in 2015 in Guangzhou, China.

As an industrial equipment manufacturer integrating research and development, engineering design, production and sales, HeJin focuses on leak testing equipment, helium leak detection systems, environmental reliability testing equipment, gas handling systems and automated manufacturing solutions.

With more than 100 employees and over 50 technical engineers, our team works closely with customers to develop practical equipment solutions for different manufacturing applications.

From initial technical discussions to equipment manufacturing and after-sales support, we aim to make every project more straightforward, reliable and efficient.

HeJin – Your Direct Manufacturing Partner for Industrial Leak Testing and Helium Recovery Solutions.

Request a Helium Recovery Solution

Looking to reduce helium consumption in your leak testing production line? Contact HeJin with your current equipment information, helium consumption and production requirements. Our engineering team can evaluate system compatibility and recommend a suitable helium recovery solution.

Contact HeJin: Website: https://www.autoparts-test.com/

Related Product Categories:

Recommended Internal Links:

Ratings & Review

Overall Rating

5.0
Based on 50 reviews for this supplier

Rating Snapshot

The following is the distribution of all ratings
5 stars
100%
4 stars
0%
3 stars
0%
2 stars
0%
1 stars
0%

All Reviews

M
Michael Turner
United States Dec 1.2025
This helium leak test machine works far better than the previous system we used. The accuracy is outstanding, and our testing efficiency improved by over 30%.
J
Jonas Weber
Germany Oct 22.2025
Die Verarbeitungsqualität ist hervorragend. Wir haben zwei Geräte für Membranspeichertests gekauft, und beide arbeiten mit bemerkenswerter Stabilität und Wiederholgenauigkeit.