logo

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Flammability Testing Equipment
Created with Pixso.

IEC 60695-11-5 Needle Flame Test Apparatus with 0.5mm Bore Burner and PLC Control for 0-1000C Flammability Testing

IEC 60695-11-5 Needle Flame Test Apparatus with 0.5mm Bore Burner and PLC Control for 0-1000C Flammability Testing

Brand Name: HeJin
Model Number: NF-2
MOQ: 1 Set
Price: Negotiatable
Payment Terms: L/C,T/T
Supply Ability: 5 sets per month
Detail Information
Place of Origin:
China
Certification:
Third party calibration certificate/ CE(cost additional)
Burner Bore:
Φ0.5 Mm ±0.1 Mm
Flame Height:
12 Mm ±1 Mm
Application Time:
5, 10, 30, 60, 120 S Selectable
Timer Accuracy:
0.1 S
Burner Tilt:
0 To 45°
Sample Stage Travel:
60 Mm XY
Power Supply:
AC 220 V 50/60 Hz, 0.8 KW
Weight:
110 Kg
Packaging Details:
Plywood
Highlight:

0.5mm Bore Burner Needle Flame Test Apparatus

,

0-1000C Needle Flame Tester

,

PLC Needle Flame Testing Equipment

Product Description
IEC 60695-11-5 Needle Flame Test Apparatus for Small Part Flame Hazard Testing

The needle flame test is the small scale companion to the glow wire test. Instead of a hot loop, a tiny premixed flame with a 12 mm height is applied to the part for a defined time, and you record whether the specimen burns, how long it burns after the flame is removed, and whether burning droplets ignite the layer of tissue underneath.

This needle flame test apparatus is designed for the samples that glow wire testing handles badly: small connectors, thin wall housings, PCBs, terminal blocks, wire harness clips and the inside of appliance cavities where a 500 g apparatus cannot fit. The burner is motorised, the flame is regulated by a mass flow controller and the whole sequence is timed by the controller, so two operators produce the same file.

Typical applications
  • Terminal blocks, relays, micro switches and PCB mounted connectors
  • Wire harnesses, cable ties, heat shrink tubing and insulation sleeves
  • Small appliance housings, hand tool bodies and charger shells
  • Electronic assemblies tested under IEC 60335-1 clause 30 and IEC 62368-1
  • Automotive interior trim samples and small electronic modules
  • Materials laboratories comparing flame retardant grades on small coupons
What this apparatus can verify
  • After flame time and after glow time of the specimen after flame removal
  • Whether burning or glowing particles ignite the tissue paper 200 mm below the sample
  • Flame spread beyond the defined area of the specimen
  • Behaviour of the part at 5 s, 10 s, 30 s, 60 s and 120 s application times
  • Repeatability between two material batches or two moulding tools
  • Compliance evidence for IEC 60695-11-5, IEC 60335-1 clause 30.2 and IEC 62368-1 Annex S
Technical parameters
Standards IEC 60695-11-5, IEC 60335-1 clause 30.2, IEC 62368-1 Annex S, GB/T 5169.5
Burner tube Stainless steel, bore Φ0.5 mm ±0.1 mm, outer diameter ≤0.9 mm, length ≥35 mm
Flame height 12 mm ±1 mm, set with the supplied gauge
Fuel Butane or propane, at least 95% purity, standard 220 g gas cartridge
Gas control Mass flow controller with digital readout, manual fine trim
Ignition Automatic ignition and flame detection, no manual lighter
Application time 5, 10, 30, 60, 120 s selectable, timer accuracy 0.1 s
Burner positioning Motorised vertical travel, tilt 0 to 45°, XY sample stage 60 mm
Test chamber Stainless chamber with darkened interior, observation window, 150 mm exhaust port
Specimen support Tissue paper layer on 10 mm pine board, 200 mm below the burner
Controller PLC with 7 inch touch screen, 30 recipes, USB log export
Safety Door interlock, gas leak detection, flame out cut off, emergency stop
Power supply AC 220 V 50/60 Hz, 0.8 kW (110 V available)
Footprint Approx. 900 x 700 x 1400 mm, weight 110 kg
Core technology and details that matter
  • Mass flow control instead of a needle valve. Flame height in a needle test depends on gas flow, and a needle valve changes with cartridge pressure and room temperature. A mass flow controller holds the flow constant as the cartridge empties, so the 12 mm flame stays 12 mm for the whole cartridge.
  • Motorised burner, timed approach. The burner travels down at a fixed speed and dwells for exactly the programmed time. The classic error in manual rigs is an operator who starts the stopwatch late or pulls the burner away early.
  • Flame detection in line. A UV sensor watches the flame. If the flame extinguishes mid test, for example because the cartridge ran out, the run aborts and is logged as invalid rather than being recorded as a pass.
  • Chamber geometry for observation. The window is large enough to film the test, and the tissue paper holder is on a pull out drawer so the paper can be inspected and photographed without disturbing the specimen.
HongCe versus typical alternatives
Comparison item HongCe needle flame apparatus Entry level flame testers European reference brands
Gas regulation Mass flow controller, flame stable to end of cartridge Needle valve, flame drops as pressure falls Mass flow, comparable
Burner motion Motorised with timed dwell Manual handle, timing by stopwatch Motorised
Flame monitoring UV detection, invalid run flagged None Usually present
Documentation CSV log with flame height and duration Paper form Software, licensed
Burner spares 0.5 mm bore burners in stock Special order Weeks of lead time
Budget level Mid range, around half of European list Lowest Highest
Quality assurance and after sales service
  • ISO 9001:2015 production, each unit flame tested and leak tested before packing
  • Factory calibration report for the mass flow controller and timer, third party certificate on request
  • 24 month warranty on controller and gas regulation, 12 months on burner and ignition
  • Burners, UV sensors, seals and tissue paper holders stocked for at least 8 years
  • English remote support within one working day, video commissioning included
  • Optional on site training in flame height setting, sample conditioning and result interpretation
Frequently asked questions

Q: Which gas should I use, butane or propane?
Either, provided purity is at least 95%. Butane cartridges are easier to buy locally in most countries and burn slightly cooler, propane gives a marginally hotter flame. The calibration procedure and the 12 mm flame reference are the same.

Q: How long does one gas cartridge last?
With a 12 mm flame and 30 s applications, a standard 220 g cartridge lasts roughly 120 to 150 tests. We recommend keeping two cartridges in stock.

Q: Can it run the 500 W and 60 s variants of the test?
Yes, application time is selectable up to 120 s, and the burner tilt and distance can be set for the alternative arrangements described in the standard.

Q: Is the flame height gauge included?
Yes, a 12 mm reference gauge and a setting procedure sheet are included with the machine.

Q: Can one controller run several chambers?
Not standard. If you need two chambers, we can supply a dual station configuration with one control cabinet and two burners, which is common in high volume appliance factories.

Q: What about delivery time?
30 to 60 days for the standard configuration.

About Guangzhou HeJin

Since 2015, Guangzhou HeJin Automation Control Technology Co., Ltd. has been engaged in the R&D and manufacturing of fire hazard and electrical safety testing equipment in Guangzhou. Our needle-flame testers and glow-wire testers are among our most popular product lines, widely supplied to home appliance manufacturers, lighting fixture factories, and third-party testing laboratories. We offer both material-level and product-level testing equipment, enabling us to design comprehensive testing solutions—covering all requirements specified in relevant standards—rather than simply selling individual pieces of equipment. Just provide us with the standards you are working to and a list of the specific clauses involved, and we will determine and configure the exact testing equipment you need.